Tesla Model 3 Owners & Service Manuals

Tesla Model 3: Thermal Management

READ NEXT:

 Cabin HVAC

 Actuator - Bleed - LH (Remove and Replace)

Remove Remove the cross car beam. See Beam - Cross Car (Remove and Replace). Disconnect the electrical wiring harness connector from the LH bleed actuator. Remove the bolts that attac

 Actuator - Intake (Remove and Replace)

Remove Remove the HVAC assembly. See HVAC Assembly (Remove and Replace). Disconnect the electrical harness from the intake actuator connector. Remove the screws (x2) that attach the int

SEE MORE:

 Tube - Input - Coolant - Power Conversion System- Install

Install Wipe up any spilled coolant Caution:  Spilled coolant can create an electrical path. O-rings in good condition Make sure that the o-rings are not damaged and that they are properly seated in the connector groove prior to inserting the tube into the power conversion system. R

 Coolant Pump - HV Battery - Install

Install Remove and discard any o-rings or debris in the superbottle where the coolant pump will install. Make sure that new o-rings are installed onto the new coolant pump. Lubricate the o-rings with Silaramic lubricant. Position the outlet of the coolant pump in the up position, and insert