Tesla Model 3: Receiver Dryer and Desiccant- Install
Install
- Use 3/8 inch extensions to press the new desiccant filter into the
condenser. Lightly tap with a hammer to fully seat the filter.
- Insert a new desiccant bag into the condenser.
- Install the inner cap into the condenser, and press it in just below the
groove for the snap ring.
- Remove the bolt from the inner cap.
- Install the snap ring into the condenser, and make sure the snap ring is
fully seated into the groove.
- Install the cap.
Torque 4 Nm
- Install the underhood reinforcement bracket onto the cooling fan module.
Note: The cooling fan module tab must be inserted into the isolator
so that the trailing tab touches the isolator rubber and the chamfered edge is
clearly visible when looking from above
Note: The trailing edge of the cooling fan module mount must
contact the lower tunnel of the isolator.
- Install the bolts (x2) that attach the underhood reinforcement bracket
to the body.
Torque 16 Nm
- Loosen the bolts (x2) for the LH cooling fan module isolator.
- Push the isolator forward, and while doing so, tighten the bolts (x2).
Torque 6 Nm
- Repeat step 9 and step 10 for the RH cooling fan module isolator.
- Perform the A/C refrigerant recharge. See A/C Refrigerant (Recovery and
Recharge).
READ NEXT:
Remove
Disconnect 12V power. See 12V Power (Disconnect and Connect).
Remove the underhood storage unit. See Underhood Storage Unit (Remove
and Replace).
Recover the A/C refrigerant. See A/C Re
Install
Install new o-rings (x2) onto the HVAC module.
Install the TXV valve onto the HVAC module, and then install the bolts
that attach the TXV valve to the HVAC module.
Torque 7.2 Nm
Ins
SEE MORE:
The charge port is located on the left side of
Model 3, behind a door that is part of the rear
tail light assembly. Before charging, park
Model 3 to ensure that the charge cable easily
reaches the charge port.
With Model 3 unlocked (or an authenticated
phone is within range) and in Park, pre
Remove
Remove the superbottle. See
Superbottle (Dual Motor) (Remove and Replace).
Install
Installation procedure is the reverse of removal.
Caution:
Perform a push-pull test to verify that the hose is fully seated