Tesla Model 3 Owners & Service Manuals

Tesla Model 3: Fuse - Power Conversion System - HV Battery- Remove

Fuse - Power Conversion System - HV Battery (Remove and Replace)

SPECIAL TOOLS

Ratchet, 1/4" Sq Dr, HV Insulated (1057602-00-A)

Ext Bar, Wobble, 1/4" Dr, HV Insulated (1057603-00-A)

Skt, 1/4" Sq Dr, 8mm, HV Insulated (1057604-00-A)

Magnet, Flexible, HV Insulated, 18" (1057607-00-A)

Asy, Service Cover, Penthouse, Model 3 (1127845-00-A)

Warning:

Only technicians who have been trained in High Voltage Awareness are permitted to perform this procedure. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, "High Voltage Awareness Care Points" for additional safety information.

Remove

  1. Remove the pyrotechnic battery disconnect from the penthouse. See Pyrotechnic Battery Disconnect (Remove and Replace).

Fuse - Power Conversion System - HV Battery- Remove

  1. Raise the high voltage controller, release the clips that attach the fuse access insulator to the RH penthouse bus cover, and remove the insulator.

Fuse - Power Conversion System - HV Battery- Remove

  1. Remove and discard the nuts that attach the power conversion system fuse to the RH penthouse bus and remove the fuse.

    READ NEXT:

     Fuse - Power Conversion System - HV Battery- Install

    Install Install the power conversion system fuse to the RH penthouse bus, and then install new nuts to attach the fuse to the bus. Torque 2.5 Nm Generic Measurement - Actual busbars and f

     Guide - Probing - HV Battery (Remove and Replace)

     Guide - Probing - HV Battery- Remove

    SPECIAL TOOLS Ratchet, 1/4" Sq Dr, HV Insulated (1057602-00-A) Ext Bar, Wobble, 1/4" Dr, HV Insulated (1057603-00-A) Skt, 1/4" Sq Dr, 13mm, HV Insulated (1057606-00-A) Magnet, Flexible, HV Insulated

    SEE MORE:

     Inverter - Rear Drive Unit - Remove

      SPECIAL TOOLS Skt, 3/8in Dr, 10EP Torx Plus External (1130479-00-A)  Caution: This procedure must not be used for replacement of a defective inverter. For inverter re

     HV Battery Air Leak Test

    Pack Enclosure Leak Tester, HV Battery (1026636-00-A) Pack Kit, Enclosure, Leak Test, HV Battery, Complete (1140501-00-A) Kit, Encl Leak Test Adapters, HV Battery (1144879-00-A) Procedure Perform the vehicle electrical isolation procedure. See Vehicle Electrical Isolation Procedure. Remove the p