Install
Install the PTC heater fuse to the RH penthouse bus, and then install
new nuts to attach the fuse to the bus.
Torque 2.5 Nm
Generic Measurement - Actual busbars and fasteners might
DRAFT
Warning:
This procedure was derived from pre-production computer models, and
might not reflect the real-world situation. Warnings and cautions might be
missing. Follow safety requirements and use extreme caution when working on or
near high voltage systems and components.
Do not redistr
Install
Install new O-rings onto the 5-way valve cover.
Note: Align notches in the o-rings with the ribs in the 5-way valve
cover.
Examine the end the of the 5-way valve stem shell shaft. One shaft
spline is slightly wider than the others.
Mark the wider spline.
Slide the new stem shell in